Santos --:--:-- BRT
문의
기술 노트 · 검정과 계측CW-RPT-07

ASTM Table 54B: Volume Correction for Fuel Oil

How ASTM Table 54B corrects fuel oil volume to 15 °C and Table 56 turns it into metric tons in air: the formulas, the constants and an example.

이 보고서는 영어로 게시되어 있으며 번역본이 곧 제공됩니다.

게시일
읽는 시간
5분
작성자
CARGOWARD® Technical Desk · 해사 검정
서비스 라인
해사 검정 →
공유

CW-DWG-202 · 연료 탱크 절개도

ASTM Table 54B is the correction every bunker survey runs: it turns a volume of fuel measured at the temperature in the tank into the volume it would occupy at 15 °C, the reference temperature of every bunker delivery note. Table 56 then turns that standard volume into metric tons in air, the figure fuel is bought and sold by. Together they make soundings taken at different temperatures, on a barge and on a ship, comparable — and a shortage provable.

Why volumes are corrected to 15 °C

A cubic metre of heavy fuel at 50 °C weighs less than a cubic metre of the same fuel at 15 °C: the molecules are further apart. A barge delivering hot fuel and a ship sounding it after it has cooled in a double-bottom tank will measure different volumes of the same oil. Neither figure is wrong; they are taken at different temperatures.

How large is the effect? A fuel oil of 975 kg/m³ shrinks by about 0.07 % for every degree it cools. A delivery measured at 48 °C and sounded again at 38 °C reads almost 0.7 % less volume — about four tonnes on a 600-tonne delivery — without a drop missing. That is more than the commercial tolerance of many supply contracts, which is why no bunker quantity is ever compared uncorrected.

The petroleum measurement tables solve this by expressing every volume at a standard temperature. ASTM D1250 (published jointly with API and the Energy Institute) has a family of tables for that purpose. Table 54A covers crude oils, Table 54B generalized products — fuel oils, jet fuels and gasolines — and Table 54D lubricating oils. Bunker fuels are generalized products, so Table 54B is the one written on bunker delivery notes.

The Table 54B formula

The 1980 tables are computed from a single equation. The thermal expansion coefficient of the fuel at 15 °C, α15\alpha_{15}, depends on its density; the correction factor follows from it and the temperature difference:

α15=K0ρ152+K1ρ15VCF=exp⁡ ⁣[−α15 Δt (1+0.8 α15 Δt)]\alpha_{15} = \frac{K_0}{\rho_{15}^{2}} + \frac{K_1}{\rho_{15}} \qquad \mathrm{VCF} = \exp\!\left[-\alpha_{15}\,\Delta t\,\left(1 + 0.8\,\alpha_{15}\,\Delta t\right)\right]

위치

ρ15\rho_{15}
Density at 15 °C, from the bunker delivery note or a laboratory testkg/m³
Δt\Delta t
Observed temperature less 15 °C, the temperature read to the nearest 0.05 °C°C
K0, K1K_0,\ K_1
Constants of the product band (table below)
VCF\mathrm{VCF}
Volume correction factor, rounded to four decimals

The constants change with the density band, because fuel oils, jet fuels and gasolines expand differently:

BandDensity at 15 °C (kg/m³)K0K1
Fuel oils838.5 to 1075.0186.96960.4862
Jet fuels787.5 to 838.5594.54180
Gasolines653.0 to 770.5346.42280.4388

Between 770.5 and 787.5 kg/m³ a transition zone uses its own form, α15=−0.00336312+2680.3206/ρ152\alpha_{15} = -0.00336312 + 2680.3206 / \rho_{15}^{2}. Marine fuels — VLSFO, HSFO, and most marine gasoil — fall in the fuel oil band or, for the lightest distillates, the jet band.

Table 56: from volume to weight in air

Fuel is traded by weight in air, not by mass in a vacuum. Air buoys up everything weighed in it; for petroleum the measurement tables account for this by subtracting 1.1 kg/m³ from the density in vacuo:

EQ. 01 — Weight conversion factor
WCF=ρ15−1.11000mair=V15×WCF\mathrm{WCF} = \frac{\rho_{15} - 1.1}{1000} \qquad m_{\text{air}} = V_{15} \times \mathrm{WCF}
Density in kg/m³; the factor in metric tons per cubic metre at 15 °C, rounded to four decimals.

The expression reproduces the printed Table 56 factors to four decimals. For a fuel of 830.0 kg/m³, for example, the table gives 1.2064 m³ per ton in air, which is 0.8289 tons per cubic metre — exactly (830.0 − 1.1) / 1000.

A worked example

A tank of heavy fuel of 991.0 kg/m³ at 15 °C is sounded at 1,250.000 m³ with an average temperature of 52.5 °C. Every step is a formula in the sheet; point at a cell to see it:

—셀을 가리키면 수식이 보입니다
Tables 54B and 56
StepValueUnit
Density at 15 °C991kg/m³
Observed temperature52.5°C
Observed volume1,250m³
α15 (fuel oil band)0.000681per °C
Δt37.5°C
VCF (Table 54B)0.9743
Volume at 15 °C (GSV)1,217.875m³
WCF (Table 56)0.9899t/m³
Metric tons in air1,205.574MT
Tables 54B and 56

The tank holds 1,205.574 metric tons in air. Its mass in a vacuum, V15×ρ15V_{15} \times \rho_{15}, would be 1,206.914 tons — the difference of 1.34 tons is the buoyancy of air, which is why the BDN and the survey must both state tons in air.

The same calculation in code

The formula is short enough to put in any spreadsheet or script. In a spreadsheet, with the density in B2 and the temperature in B3:

Excel
=ROUND(EXP(-(186.9696/B2^2+0.4862/B2)*(B3-15)*(1+0.8*(186.9696/B2^2+0.4862/B2)*(B3-15))),4)

And in Python, with the rounding of the tables:

Pythonastm.py
from decimal import Decimal, ROUND_HALF_UP
from math import exp

def r(x, digits):
    """Half-up rounding on the figure as written, like the printed tables."""
    return float(Decimal(str(x)).quantize(Decimal(1).scaleb(-digits), rounding=ROUND_HALF_UP))

def vcf_54b(rho15, temp_c):
    t = r(round(temp_c / 0.05) * 0.05, 2)     # the tables read the temperature to 0.05 °C
    a = 186.9696 / rho15**2 + 0.4862 / rho15  # fuel oils, 838.5 to 1075 kg/m3
    dt = t - 15
    return r(exp(-a * dt * (1 + 0.8 * a * dt)), 4)

def wcf_56(rho15):
    return r((rho15 - 1.1) / 1000, 4)         # density in vacuo less air buoyancy

v15 = r(1250.000 * vcf_54b(991.0, 52.5), 3)
print(v15, r(v15 * wcf_56(991.0), 3))         # 1217.875 1205.574

Rounding that changes the result

The tables are exact about rounding, and a survey that ignores it can disagree with the BDN by a few hundred kilograms on a large delivery:

  • The observed temperature is taken to the nearest 0.05 °C before the factor is computed.
  • The VCF and the WCF are rounded to four decimals, half up.
  • Volumes at 15 °C and tons are rounded to three decimals.
  • Each tank is corrected at its own temperature before the tanks are added; averaging the temperatures first gives a different answer.
The 1980 tables and the 2004 standard

In 2004 the standard was revised (ASTM D1250-04, API MPMS Chapter 11.1): the printed tables were replaced by an implementation procedure that computes the correction directly, with its own rounding and an extended range. The difference from the 1980 Table 54B is small for marine fuels, but it is not zero. Many bunker delivery notes and supply contracts still name "Table 54B"; when they do, use the 1980 formula and its rounding. When a contract names the 2004 procedure, use it — and make sure both sides use the same one.

These are the corrections behind every bunker survey that detects the cappuccino effect. The BQS & LOP generator applies them tank by tank, at each tank's temperature, and reconciles the result with the BDN; the desk's marine survey team does the same on board in Brazilian ports.

Questions about Table 54B

Is Table 54B the same as Table 6B?

They do the same job in different units. Table 54B works in density at 15 °C and degrees Celsius; Table 6B in API gravity and degrees Fahrenheit, correcting to 60 °F. Bunker delivery notes in metric ports use 54B.

Why 1.1 kg/m³ for air?

It is the allowance the measurement tables make for the buoyancy of air on petroleum weighed in air, applied to the density in vacuo.

What if the density is outside the fuel oil band?

Use the band the density falls in: jet fuels, the transition zone or gasolines each have their own constants. Very heavy fuels above 1075 kg/m³ are outside the table's range.

출처

  1. ASTM D1250: Standard Guide for the Use of the Joint API and ASTM Adjunct for Temperature and Pressure Volume Correction FactorsASTM International
  2. Manual of Petroleum Measurement Standards, Chapter 11.1American Petroleum Institute · 2004
  3. Fuel oil density and volume correction (ASTM D1250)The Engineering ToolBox

실무에 적용하기

T-06BQS·LOP 생성기ASTM 표 54B·56으로 바지선 BDN과 본선 측심 대조: 부족량, 공기 혼입 점검, 항의서도구 열기

SVC-04 · 서비스

해사 검정

흘수표, 탱크, 화물창에서 입회하는 독립 검정인. 선주, 용선자, P&I 클럽이 믿을 수 있는 계산표와 사진 기록을 남깁니다.

이메일로 받는 보고서

새 보고서를 받은편지함으로.

데스크의 방법, 수치, 증거: 보고서가 발행될 때 사용하시는 언어로 이메일 한 통, 그 외에는 없습니다.

보내 드리는 링크로 확인하신 후, 보고서가 발행될 때마다 이메일 한 통을 보냅니다. 언제든 구독을 해지할 수 있습니다. 개인정보 처리방침

운영 데스크 · 24/7

운영 지원을 요청하세요. 데스크가 24/7 응답합니다.

선박, 항만, ETA를 알려주세요. 콜센터가 아닌 코디네이터가 밤낮없이 15분 이내에 회신합니다.

계획 요청