LETTER OF PROTEST
- ____________, bunker supplier
- The Master, bunker barge ____________
Subject: Short delivery of VLSFO: 18.154 MT (1.79 %) - BDN No. ____________ - M/V ____________
Dear Sirs,
Please be advised that upon completion of bunkering operations at Santos on 2026-11-10 (commenced 08:30, completed 14:10 local time), a discrepancy of 18.154 MT was found between the Vessel's measurements and the BDN figures.
The Bunker Delivery Note No. ____________ gives VLSFO 1,050.000 m³ observed at 42.5 °C with a density of 985.4 kg/m³ at 15 °C: 1,030.050 m³ at 15 °C (VCF 0.9810, ASTM D1250 Table 54B) and 1,013.878 MT in air (WCF 0.9843, Table 56).
The Vessel's soundings of her 3 bunker tanks before the delivery (the quantity remaining on board) and after it, each corrected to 15 °C at its own temperature, give 1,011.606 m³ at 15 °C received, that is 995.724 MT in air at a density of 985.4 kg/m³ at 15 °C (the BDN density).
The quantity received is therefore 18.154 MT (1.79 %) short of the BDN quantity, beyond the commercial tolerance of 0.50 %.
The temperature declared by the barge, 42.5 °C, is 2.2 °C below the temperature of the product as received on board, 44.7 °C (from the Vessel's tank temperatures). At the temperature measured on board the BDN figures give 1,012.328 MT: the declared temperature adds 1.550 MT to the BDN quantity.
We therefore hereby lodge our formal protest and hold you fully responsible for the shortage of 18.154 MT, together with all consequences, losses, delays and expenses arising therefrom. Owners and Charterers reserve all their rights in this respect, including the right to claim compensation and to have the retained samples analysed.
Samples were drawn at the Vessel's manifold throughout the delivery and sealed; they are retained on board and available for joint analysis.
We request a joint re-measurement of the barge's tanks and an immediate investigation of the matter, and ask you to acknowledge receipt of this letter.
All quantities are calculated in accordance with ASTM D1250 (Table 54B for the volume correction to 15 °C, Table 56 for the conversion to metric tons in air); the full figures are in bunker quantity survey report CW-BQS. This letter is issued without prejudice to any of the rights of the Vessel, her Owners and Charterers, all of which are expressly reserved.
Yours faithfully,
Received for receipt only, not as acceptance of its contents:
____________Master, bunker barge ____________, for and on behalf of ____________Date and time: ____________